{"product_id":"halo-tweeze-uv-led-tweezer-light","title":"Halo Tweeze - UV \/ LED Tweezer Light","description":"\u003ch1\u003e\u003cspan\u003eIntroducing the Halo Tweeze\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003ePremium Wireless UV LED Tweezer Light\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlso \u003ca href=\"https:\/\/evlolash.com\/products\/halo-tweeze-light-kit\"\u003eavailable as a kit\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAfter months of testing, refining, and perfecting every detail, the Halo Tweeze is finally here.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned to make UV lash application faster, lighter, and more convenient, this innovative tweezer features a built-in UV light and a wireless foot pedal connection, eliminating unnecessary cords around your workspace.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe lightweight, ergonomic design weighs just 20 grams and can be comfortably used by both right- and left-handed lash artists.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eReplaceable Light Module\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Halo Tweeze features a separately replaceable light plug module. If the module ever needs to be replaced, or an updated version becomes available, you can simply replace the module instead of purchasing an entirely new tweezer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEach Halo Tweeze comes standard with the Original Wide Beam \u003ca href=\"%20https:\/\/evlolash.com%20%E2%80%BA%20products%20%E2%80%BA%20halo-tweeze-light-plug-only\"\u003eLight Plug Module.\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible UV Adhesive\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHalo Tweeze works best with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efast-curing, clear UV adhesive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. For the fastest and most consistent cure with the Tweeze, we recommend \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHalo Bolt or Halo Fuse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTinted or black UV adhesives are not recommended for use with the Tweeze. Because the Tweeze uses a lower-powered, highly targeted light source, pigments in darker adhesives can absorb or reduce the amount of light reaching the photoinitiator throughout the adhesive. This may result in a slower or less consistent cure compared with a clear adhesive.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor best results, pair the Tweeze with a clear UV adhesive formulated to cure within the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e395–405 nm wavelength range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWireless Foot Pedal\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe wireless foot pedal is powered by AAA batteries and is individually programmed to its corresponding Halo Tweeze.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEach foot pedal is paired with one specific tweezer light and is not interchangeable. When working alongside other lash artists, always keep each foot pedal with its assigned tweezer light to avoid mixing the devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSmart Light Activation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePress the foot pedal to activate the light. After the pedal is released, the light will remain illuminated for an additional three seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAfter approximately two minutes of inactivity, the Halo Tweeze will automatically power off to help preserve battery life.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRechargeable Battery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Halo Tweeze is powered by a rechargeable battery that provides up to approximately 48 hours of use per full charge (results will vary depending on usage).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe light output remains consistent until the battery is depleted, so you do not have to worry about reduced curing performance as the battery level decreases.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA complete charge may take up to two hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe battery is designed to withstand approximately 500 full charging cycles before the available runtime may gradually begin to decrease.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCharging Instructions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOnly use the charging cord and power adapter included with the Halo Tweeze.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUsing a higher-powered charging cord, block, or adapter may cause battery deterioration, reduce the lifespan of the battery, and void the product warranty.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"isSelectedEnd\"\u003e\u003cspan\u003eTweezer Compatability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur Tweezer Light should work with most tweezers, but you might want to play with different styles to see what works best for your. Our kit comes with our Biggie Tweezer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHalo Tweeze Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUVA wavelength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 395–405 nm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInput:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 5V \/ 1A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMaterials:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Aluminum, silicone, and metal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 20g\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLight module:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Original Wide Beam Light Plug Module\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOrientation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Suitable for right- and left-handed lash artists\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBattery runtime:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to approximately 48 hours per charge\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCharging time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to two hours\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBattery lifespan:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 500 charging cycles\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFoot pedal:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Wireless and powered by AAA batteries (included)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Halo Tweeze is backed by our standard one-year warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eReturns\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003ePlease note: Halo Tweeze is a technique-dependent professional tool and we cannot offer refunds for Halo Tweeze. However, if you try it for 30 days — if it isn't right for your lashing style, return it for store credit for the tweezer's purchase price. Excludes other kit contents. See our \u003ca href=\"https:\/\/evlolash.com\/policies\/refund-policy\"\u003eRefund Policy\u003c\/a\u003e for more details.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"1114\" height=\"813\" src=\"https:\/\/www.youtube.com\/embed\/w7P-vU2Ruls\" title=\"Halo Tweeze Tutorial- How to use and take care of your Halo Tweeze\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"1114\" height=\"813\" src=\"https:\/\/www.youtube.com\/embed\/d3wlK8YhbfE\" title=\"Halo Tweeze Light Plugs, What the difference is and how to use them.\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHalo Tweeze: Photobiological Safety Testing \u0026amp; Exposure Assessment\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eUnderstanding the Safety Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Halo Tweeze has undergone independent photobiological safety testing in accordance with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIEC 62471:2006\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the international standard used to evaluate potential light-related hazards to the skin and eyes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTesting was performed by EMTEK (Dongguan) Co., Ltd. on July 10, 2026, at a measurement distance of 20 cm (approximately 8 inches).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Halo Tweeze received a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRisk Group 1 (RG1 – Low Risk)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e classification under these laboratory test conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhy Was the Tweeze Tested at 20 cm?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIEC 62471 specifies a standardized measurement distance of 20 cm for this category of light source. This allows laboratories to evaluate light emissions under consistent, internationally recognized testing conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHowever, the Halo Tweeze is designed to operate much closer to the lash line, typically between 3 and 6 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the standardized laboratory test was conducted at 20 cm, those measurements alone do not represent the light intensity at the closer distances used during an actual lash application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTo better understand exposure under normal professional operating conditions, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ean additional photobiological engineering assessment was completed using the independent laboratory measurements as its foundation.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eEvaluating Exposure at Actual Working Distances \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0583\/8313\/8986\/files\/tweeze_working_distance.png?v=1795447619\" alt=\"roanefamily.myshopify.com image\" width=\"236\" height=\"295\" style=\"float: right;\"\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe additional assessment evaluated potential exposure at the Halo Tweeze's intended working distances of 3–6 cm, using established optical principles, including the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einverse-square law\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe inverse-square law describes how light intensity changes with distance from a source. For an ideal point source, as the distance decreases, the irradiance increases in proportion to the inverse square of that distance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor example, using the 20 cm laboratory measurements as a reference:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAt 6 cm, the projected irradiance is approximately 11.1 times the measured value at 20 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAt 3 cm, the projected irradiance is approximately 44.4 times the measured value at 20 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese calculations allow us to estimate the light intensity at the closer distances where the Halo Tweeze is used.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe assessment also considered additional photobiological hazards, including UVA exposure, blue-light exposure, and retinal thermal hazards. Radiance-related hazards were evaluated separately rather than simply applying inverse-square calculations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe findings:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The engineering assessment concluded that the evaluated exposure levels remained within the applicable Risk Group 1 criteria throughout the intended 3–6 cm working range, based on activations limited to 3 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is important to distinguish between the two evaluations: the RG1 laboratory classification was established through direct testing at 20 cm, while the closer-distance findings were determined through engineering projections and evaluation, not separate laboratory measurements at those distances.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePutting UV Exposure Into Perspective\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOne way to understand the estimated UV exposure is to compare the Halo Tweeze's hazard-weighted actinic UV intensity with that of strong midday sunlight.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActinic UV is a measurement of ultraviolet radiation weighted according to its potential biological effects on the skin and eyes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUsing the engineering assessment's projected value at 3 cm:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eStrong midday sunlight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 0.70 W\/m² of hazard-weighted actinic UV.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHalo Tweeze at 3 cm:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 0.00827 W\/m² of projected hazard-weighted actinic UV.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eUnder these comparison conditions, the Halo Tweeze produces approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e85 times less hazard-weighted actinic UV intensity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e than the sunlight reference.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis means approximately 1 hour and 25 minutes of continuous Halo Tweeze illumination at 3 cm would produce the same calculated hazard-weighted actinic UV dose as 1 minute of strong midday sunlight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat About an Entire Lash Set?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eUnlike continuous light exposure, the Halo Tweeze is activated in short intervals during adhesive curing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConsider a full lash set with 300 lash bonds, each receiving 3 seconds of illumination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e300 bonds × 3 seconds = 900 seconds, or 15 minutes of cumulative illumination.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBased on the projected actinic UV intensity at 3 cm, this cumulative exposure would be equivalent to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10.6 seconds of strong midday sunlight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in terms of calculated hazard-weighted actinic UV dose.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis comparison is intended to provide perspective on the relatively low estimated actinic UV exposure associated with the device. It does not imply that sunlight exposure and Halo Tweeze exposure have identical biological effects or that the same risks apply to every tissue or exposure condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat Does This Mean for Lash Artists?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Halo Tweeze has been evaluated through two complementary approaches: independent laboratory testing at the standardized 20 cm distance and an additional engineering assessment addressing its closer professional working range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTogether, these evaluations provide a scientific basis for understanding the device's photobiological exposure characteristics when used according to manufacturer instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe closer-distance calculations are estimates derived from measured data and optical modeling. The inverse-square law provides an approximation, and actual irradiance at very short distances may be affected by the LED's geometry, optics, and beam distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor professional use, maintain the recommended 3–6 cm working distance, keep the client's eyes fully closed, use appropriate UV eye protection, avoid direct viewing of the LED, and do not modify the device's 3-second automatic shutoff.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThe key takeaway:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The Halo Tweeze's low-risk laboratory classification, combined with its intended-use engineering assessment, provides supporting safety data for professional lash curing. Understanding both the measured results and the modeled estimates allows lash artists to make informed decisions while following appropriate safety protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"EvLo Lash Co.","offers":[{"title":"Default Title","offer_id":68216543412439,"sku":"HALO_TWEEZE_BLACK","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0288\/4508\/0635\/files\/1_8ea77d2f-413a-4ca5-8029-591df53decaa.png?v=1795536732","url":"https:\/\/awlashes.com\/products\/halo-tweeze-uv-led-tweezer-light","provider":"AW Lashes","version":"1.0","type":"link"}