Introducing the Halo Tweeze

Premium Wireless UV LED Tweezer Light

Also available as a kit.

After months of testing, refining, and perfecting every detail, the Halo Tweeze is finally here.

Designed to make UV lash application faster, lighter, and more convenient, this innovative tweezer features a built-in UV light and a wireless foot pedal connection, eliminating unnecessary cords around your workspace.

The lightweight, ergonomic design weighs just 20 grams and can be comfortably used by both right- and left-handed lash artists.

Replaceable Light Module

The Halo Tweeze features a separately replaceable light plug module. If the module ever needs to be replaced, or an updated version becomes available, you can simply replace the module instead of purchasing an entirely new tweezer.

Each Halo Tweeze comes standard with the Original Wide Beam Light Plug Module.

Compatible UV Adhesive

Halo Tweeze works best with a fast-curing, clear UV adhesive. For the fastest and most consistent cure with the Tweeze, we recommend Halo Bolt or Halo Fuse.

Tinted or black UV adhesives are not recommended for use with the Tweeze. Because the Tweeze uses a lower-powered, highly targeted light source, pigments in darker adhesives can absorb or reduce the amount of light reaching the photoinitiator throughout the adhesive. This may result in a slower or less consistent cure compared with a clear adhesive.

For best results, pair the Tweeze with a clear UV adhesive formulated to cure within the 395–405 nm wavelength range.

Wireless Foot Pedal

The wireless foot pedal is powered by AAA batteries and is individually programmed to its corresponding Halo Tweeze.

Each foot pedal is paired with one specific tweezer light and is not interchangeable. When working alongside other lash artists, always keep each foot pedal with its assigned tweezer light to avoid mixing the devices.

Smart Light Activation

Press the foot pedal to activate the light. After the pedal is released, the light will remain illuminated for an additional three seconds.

After approximately two minutes of inactivity, the Halo Tweeze will automatically power off to help preserve battery life.

Rechargeable Battery

The Halo Tweeze is powered by a rechargeable battery that provides up to approximately 48 hours of use per full charge (results will vary depending on usage).

The light output remains consistent until the battery is depleted, so you do not have to worry about reduced curing performance as the battery level decreases.

A complete charge may take up to two hours.

The battery is designed to withstand approximately 500 full charging cycles before the available runtime may gradually begin to decrease.

Charging Instructions

Only use the charging cord and power adapter included with the Halo Tweeze.

Using a higher-powered charging cord, block, or adapter may cause battery deterioration, reduce the lifespan of the battery, and void the product warranty.

Tweezer Compatability

Our Tweezer Light should work with most tweezers, but you might want to play with different styles to see what works best for your. Our kit comes with our Biggie Tweezer.

Halo Tweeze Specifications

  • UVA wavelength: 395–405 nm
  • Power: 1W
  • Input: 5V / 1A
  • Materials: Aluminum, silicone, and metal
  • Weight: 20g
  • Light module: Original Wide Beam Light Plug Module
  • Orientation: Suitable for right- and left-handed lash artists
  • Battery runtime: Up to approximately 48 hours per charge
  • Charging time: Up to two hours
  • Battery lifespan: Approximately 500 charging cycles
  • Foot pedal: Wireless and powered by AAA batteries (included)

Warranty

The Halo Tweeze is backed by our standard one-year warranty.

Returns

Please note: Halo Tweeze is a technique-dependent professional tool and we cannot offer refunds for Halo Tweeze. However, if you try it for 30 days — if it isn't right for your lashing style, return it for store credit for the tweezer's purchase price. Excludes other kit contents. See our Refund Policy for more details.

 

Halo Tweeze: Photobiological Safety Testing & Exposure Assessment

Understanding the Safety Testing

The Halo Tweeze has undergone independent photobiological safety testing in accordance with IEC 62471:2006, the international standard used to evaluate potential light-related hazards to the skin and eyes.

Testing was performed by EMTEK (Dongguan) Co., Ltd. on July 10, 2026, at a measurement distance of 20 cm (approximately 8 inches).

The Halo Tweeze received a Risk Group 1 (RG1 – Low Risk) classification under these laboratory test conditions.

Why Was the Tweeze Tested at 20 cm?

IEC 62471 specifies a standardized measurement distance of 20 cm for this category of light source. This allows laboratories to evaluate light emissions under consistent, internationally recognized testing conditions.

However, the Halo Tweeze is designed to operate much closer to the lash line, typically between 3 and 6 cm.

Because the standardized laboratory test was conducted at 20 cm, those measurements alone do not represent the light intensity at the closer distances used during an actual lash application.

To better understand exposure under normal professional operating conditions, an additional photobiological engineering assessment was completed using the independent laboratory measurements as its foundation.

Evaluating Exposure at Actual Working Distances roanefamily.myshopify.com image

The additional assessment evaluated potential exposure at the Halo Tweeze's intended working distances of 3–6 cm, using established optical principles, including the inverse-square law.

The inverse-square law describes how light intensity changes with distance from a source. For an ideal point source, as the distance decreases, the irradiance increases in proportion to the inverse square of that distance.

For example, using the 20 cm laboratory measurements as a reference:

  • At 6 cm, the projected irradiance is approximately 11.1 times the measured value at 20 cm.

  • At 3 cm, the projected irradiance is approximately 44.4 times the measured value at 20 cm.

These calculations allow us to estimate the light intensity at the closer distances where the Halo Tweeze is used.

The assessment also considered additional photobiological hazards, including UVA exposure, blue-light exposure, and retinal thermal hazards. Radiance-related hazards were evaluated separately rather than simply applying inverse-square calculations.

The findings: The engineering assessment concluded that the evaluated exposure levels remained within the applicable Risk Group 1 criteria throughout the intended 3–6 cm working range, based on activations limited to 3 seconds.

It is important to distinguish between the two evaluations: the RG1 laboratory classification was established through direct testing at 20 cm, while the closer-distance findings were determined through engineering projections and evaluation, not separate laboratory measurements at those distances.

Putting UV Exposure Into Perspective

One way to understand the estimated UV exposure is to compare the Halo Tweeze's hazard-weighted actinic UV intensity with that of strong midday sunlight.

Actinic UV is a measurement of ultraviolet radiation weighted according to its potential biological effects on the skin and eyes.

Using the engineering assessment's projected value at 3 cm:

  • Strong midday sunlight: Approximately 0.70 W/m² of hazard-weighted actinic UV.

  • Halo Tweeze at 3 cm: Approximately 0.00827 W/m² of projected hazard-weighted actinic UV.

Under these comparison conditions, the Halo Tweeze produces approximately 85 times less hazard-weighted actinic UV intensity than the sunlight reference.

This means approximately 1 hour and 25 minutes of continuous Halo Tweeze illumination at 3 cm would produce the same calculated hazard-weighted actinic UV dose as 1 minute of strong midday sunlight.

What About an Entire Lash Set?

Unlike continuous light exposure, the Halo Tweeze is activated in short intervals during adhesive curing.

Consider a full lash set with 300 lash bonds, each receiving 3 seconds of illumination.

300 bonds × 3 seconds = 900 seconds, or 15 minutes of cumulative illumination.

Based on the projected actinic UV intensity at 3 cm, this cumulative exposure would be equivalent to approximately 10.6 seconds of strong midday sunlight in terms of calculated hazard-weighted actinic UV dose.

This comparison is intended to provide perspective on the relatively low estimated actinic UV exposure associated with the device. It does not imply that sunlight exposure and Halo Tweeze exposure have identical biological effects or that the same risks apply to every tissue or exposure condition.

What Does This Mean for Lash Artists?

The Halo Tweeze has been evaluated through two complementary approaches: independent laboratory testing at the standardized 20 cm distance and an additional engineering assessment addressing its closer professional working range.

Together, these evaluations provide a scientific basis for understanding the device's photobiological exposure characteristics when used according to manufacturer instructions.

The closer-distance calculations are estimates derived from measured data and optical modeling. The inverse-square law provides an approximation, and actual irradiance at very short distances may be affected by the LED's geometry, optics, and beam distribution.

For professional use, maintain the recommended 3–6 cm working distance, keep the client's eyes fully closed, use appropriate UV eye protection, avoid direct viewing of the LED, and do not modify the device's 3-second automatic shutoff.

The key takeaway: The Halo Tweeze's low-risk laboratory classification, combined with its intended-use engineering assessment, provides supporting safety data for professional lash curing. Understanding both the measured results and the modeled estimates allows lash artists to make informed decisions while following appropriate safety protocols.